Conventional Drainage

Conventional (gravity) roof rainwater drainage: design, installation and testing of outlets, downpipes and collector pipes. Site survey and quotation by HYDRATERM.

CONVENTIONAL DRAINAGE · GRAVITY · DOWNPIPES · ROOF OUTLETS

Conventional Drainage
A System That Discharges Rainwater by Natural Fall and Gravity.

Conventional drainage is the traditional solution that safely carries rainwater away from roofs, terraces, balconies and outdoor areas by gravity, through outlets, gutters, downpipes and horizontal pipes.

Request a Quote for Your Project →
OVERVIEW

Conventional drainage discharges rainwater by fall and gravity.

The system consists of roof outlets, gutters, downpipes, horizontal collector pipes, manholes and external discharge connections.

Conventional rainwater drainage is the most widely used roof drainage system. The fall of the roof surface directs water to outlets or gutters, from where downpipes carry it to ground level or to the rainwater drain.

It is a practical, economical and easy-to-maintain solution for residential buildings, small and medium-sized commercial buildings, balconies, terraces, car park ramps and traditional roofs.

CONVENTIONAL SYSTEM COMPONENTS

Which details matter in conventional drainage?

The roof area, fall, number of outlets, pipe diameter, downpipe positions and external discharge directly affect system performance.

Roof Outlets
ROOF OUTLET

Roof Outlets and Collection Points

Roof outlets are the first point at which rainwater passes from the roof surface into the drainage pipework. On flat roofs, terraces and balconies, the position and level of outlets must be planned carefully to prevent ponding.

If too few outlets are provided, water can pond on the roof during heavy rainfall. This creates risks such as damage to waterproofing, overflowing parapets, ceiling leaks and additional structural loads.

Technical installation details

The number of outlets must be determined according to the roof area and regional rainfall intensity.
On flat roofs, outlets must be placed at the lowest points.
Leaf guards and debris strainers make maintenance easier.
An emergency overflow outlet or parapet overflow must also be considered.
FunctionTo take rainwater from the roof surface into the drainage pipework
Suitable applicationsFlat roofs, terraces, balconies, car park decks, plant roof areas
Points to noteOutlet level, waterproofing detail, leaf guard, overflow line, maintenance access
Downpipes
DOWNPIPE

Rainwater Downpipes

Downpipes carry rainwater collected on the roof vertically down to ground level or to the external rainwater drain. The pipe diameter must be selected according to the roof area and the volume of water to be discharged.

Downpipes may be exposed on the façade or routed through a shaft inside the building. For internal pipes, condensation, noise, maintenance access and tightness must also be considered.

Technical installation details

On houses and small buildings, downpipes are usually Ø75, Ø90, Ø100 or Ø110 mm.
On large roofs, the pipe diameter and number of downpipes must be determined by calculation.
Pipes exposed on the façade must be made of materials suited to UV, impact and frost.
Acoustic and anti-condensation insulation can be considered for rainwater pipes running inside the building.
Typical diametersØ75, Ø90, Ø100, Ø110 mm; Ø125 / Ø160 mm depending on the project
Pipes usedPVC, PP, HDPE, steel, aluminium or gutter and downpipe profiles according to the system
RisksInsufficient diameter, frost, staining on the façade, blockages, leaking joints
Gutter Systems
GUTTER SYSTEM

Gutters and Horizontal Collector Pipes

On pitched roofs, rainwater is usually collected by gutters and carried to the downpipes. The gutter cross-section must be selected according to the roof surface, rainfall and spacing of the downpipes.

An insufficient gutter cross-section, incorrect fall or too few downpipes can cause overflowing, staining of the façade, water collecting around the foundations and damage to waterproofing.

Technical installation details

The gutter fall must allow water to flow freely to the downpipe.
Gutter brackets must be fixed at sufficient intervals to withstand wind, snow loads and the weight of water.
Maintenance access must be provided for clearing leaves and debris.
The number of downpipes can be increased according to the gutter length and roof area.
Suitable applicationsPitched roofs, houses, small commercial buildings, garage and warehouse roofs
Material optionsPVC, galvanised steel, aluminium, zinc, copper and coated metal gutter systems
Points to noteGutter fall, downpipe spacing, leaf guards, snow load, façade connections
External Discharge Connection
EXTERNAL DISCHARGE

External Rainwater Discharge

Rainwater from the roof must be connected to a safe discharge line at ground level. This can lead to the municipal storm drain, a soakaway, a rainwater storage tank or controlled surface drainage.

If downpipes discharge directly around the building’s foundations, damp in the basement, water collecting around the foundations, frost damage and surface deterioration can occur. External discharge is therefore an important part of the system.

Technical installation details

External pipes are usually PVC-U, PP or sewer/rainwater pipes of a suitable SN class.
The pipe diameter must be calculated according to the roof area and the number of downpipes connected to the same line.
Manholes, inspection chambers and access covers are important for maintenance.
If there is a risk of rainwater backflow, a non-return valve or overflow protection should be considered.
Main drain diametersØ110, Ø125, Ø160, Ø200 mm and larger diameters as required by the project
Discharge pointStorm drain, manhole, soakaway, storage tank or controlled surface discharge
Points to noteLevels, fall, frost depth, traffic loads, manhole access, risk of backflow
SUMMARY FOR CLIENTS

What should you consider when choosing a conventional drainage system?

1. The number of outlets and downpipes must be calculated correctly.

If too few downpipes are provided for the roof area, overflowing and ponding can occur during heavy rainfall.

2. Falls and levels must be correct.

Incorrect falls on roofs, gutters, terraces and external pipes can cause standing water or backflow.

3. Maintenance access must be provided.

Outlets, gutters, downpipes, manholes and access covers must be accessible for regular cleaning.

4. Water must not be discharged uncontrolled around the foundations.

Rainwater must be carried away from the building’s foundations and connected to a suitable drainage or rainwater line.

Let’s plan the right conventional drainage system for your roof and outdoor areas.

We will prepare a safe rainwater solution based on the roof area, gutter size, number of downpipes, outlet capacity and external discharge.

Request a Quote →