Vaillant uniSTOR plus VIH R 120–200 (B)
Cylindrical single-coil hot-water cylinder for boilers and combi boilers.
- Tek serpantin
- 120–200 l

VIH R 120/6 B
- Volume
- 117 l
- Standby heat loss
- 1,1 kWh/24h
- Dimensions
- 853 × 590 × 590 mm
- Empty weight
- 68 kg
- Max. pressure
- 10 bar

VIH R 150/6 B
- Volume
- 144 l
- Standby heat loss
- 1,2 kWh/24h
- Dimensions
- 988 × 590 × 590 mm
- Empty weight
- 79 kg
- Max. pressure
- 10 bar

VIH R 200/6 B
- Volume
- 184 l
- Standby heat loss
- 1,3 kWh/24h
- Dimensions
- 1.206 × 590 × 590 mm
- Empty weight
- 97 kg
- Max. pressure
- 10 bar

Vaillant uniSTOR exclusive VIH R 120–200 (M)
Single-coil cylinder with enhanced insulation to reduce heat loss.
- Enhanced insulation
- 120–200 l

VIH R 120/6 M
- Volume
- 117 l
- Coil surface area
- 0,7 m²
- Standby heat loss
- 0,74 kWh/24h
- Dimensions
- 955 × 590 × 590 mm
- Empty weight
- 68 kg
- Max. pressure
- 10 bar

VIH R 150/6 M
- Volume
- 144 l
- Coil surface area
- 0,9 m²
- Standby heat loss
- 0,77 kWh/24h
- Dimensions
- 1.076 × 590 × 590 mm
- Empty weight
- 79 kg
- Max. pressure
- 10 bar

VIH R 200/6 M
- Volume
- 184 l
- Coil surface area
- 1 m²
- Standby heat loss
- 0,83 kWh/24h
- Dimensions
- 1.314 × 590 × 590 mm
- Empty weight
- 97 kg
- Max. pressure
- 10 bar

Vaillant uniSTOR plus VIH R 300–500
Single-coil cylinders of 300–500 litres for high hot-water demand.
- 300–500 l

VIH R 300/3 BR
- Volume
- 294 l
- Coil surface area
- 1,5 m²
- Standby heat loss
- 1,40 kWh/24h
- Dimensions
- 1.804 × 650 × 755 mm
- Empty weight
- 103 kg
- Max. pressure
- 10 bar

VIH R 400/3 BR
- Volume
- 398 l
- Coil surface area
- 1,7 m²
- Standby heat loss
- 1,52 kWh/24h
- Dimensions
- 1.502 × 790 × 900 mm
- Empty weight
- 136 kg
- Max. pressure
- 10 bar

VIH R 500/3 BR
- Volume
- 490 l
- Coil surface area
- 2,3 m²
- Standby heat loss
- 1,78 kWh/24h
- Dimensions
- 1.802 × 790 × 900 mm
- Empty weight
- 170 kg
- Max. pressure
- 10 bar

Vaillant uniSTOR exclusive VIH R 300
300-litre single-coil cylinder with enhanced insulation.
- Enhanced insulation
- 300 l

VIH R 300/3 MR
- Volume
- 294 l
- Coil surface area
- 1,5 m²
- Standby heat loss
- 1,16 kWh/24h
- Dimensions
- 1.929 × 690 × 775 mm
- Empty weight
- 115 kg
- Max. pressure
- 10 bar

Vaillant uniSTOR plus VIH RW 200
Hot-water cylinder with a large-surface coil for heat pumps.
- For heat pumps
- Large coil

VIH RW 200/2 B
- Volume
- 185 l
- Coil surface area
- 1,9 m²
- Standby heat loss
- 1,25 kWh/24h
- Dimensions
- 1.253 × 596 × 596 mm
- Empty weight
- 80 kg
- Max. pressure
- 10 bar

Vaillant uniSTOR plus VIH RW 300–500
300–500-litre cylinders with large coils designed for heat pumps.
- For heat pumps
- 300–500 l

VIH RW 300/3 BR
- Volume
- 281 l
- Coil surface area
- 3,12 m²
- Standby heat loss
- 1,40 kWh/24h
- Dimensions
- 1.804 × 650 × 755 mm
- Empty weight
- 141 kg
- Max. pressure
- 10 bar

VIH RW 400/3 BR
- Volume
- 375 l
- Coil surface area
- 4,42 m²
- Standby heat loss
- 1,54 kWh/24h
- Dimensions
- 1.502 × 790 × 900 mm
- Empty weight
- 181 kg
- Max. pressure
- 10 bar

VIH RW 500/3 BR
- Volume
- 460 l
- Coil surface area
- 5,90 m²
- Standby heat loss
- 1,84 kWh/24h
- Dimensions
- 1.802 × 790 × 900 mm
- Empty weight
- 235 kg
- Max. pressure
- 10 bar

Vaillant uniSTOR exclusive VIH RW
Heat-pump cylinders with large coils and enhanced insulation.
- For heat pumps
- Enhanced insulation

VIH RW 300/3
- Volume
- 281 l
- Coil surface area
- 3,12 m²
- Standby heat loss
- 1,05 kWh/24h
- Dimensions
- 1.929 × 690 × 775 mm
- Empty weight
- 153 kg
- Max. pressure
- 10 bar

VIH RW 400/3
- Volume
- 375 l
- Coil surface area
- 4,42 m²
- Standby heat loss
- 1,16 kWh/24h
- Dimensions
- 1.633 × 850 × 930 mm
- Empty weight
- 195 kg
- Max. pressure
- 10 bar

Vaillant uniSTOR VIH Q 75
Compact cuboid hot-water cylinder installed below or beside the boiler.
- Kompakt
- 68 l

VIH Q 75/2 B
- Volume
- 68 l
- Coil surface area
- 0,85 m²
- Standby heat loss
- 0,9 kWh/24h
- Dimensions
- 440 × 440 × 720 mm
- Empty weight
- 50 kg
- Max. pressure
- 10 bar

Vaillant actoSTOR VIH Q
Compact hot-water storage using a plate-heat-exchanger charging system.
- Kompakt
- Cylinder charging system

VIH QL 75/2 B
- Volume
- 72 l
- Standby heat loss
- 0,9 kWh/24h
- Dimensions
- 440 × 440 × 720 mm
- Empty weight
- 38 kg
- Max. pressure
- 10 bar

Vaillant actoSTOR VIH K
Stratified storage delivering a large volume of hot water quickly.
- Stratified charging

VIH K 300
- Volume
- 150 l
- Standby heat loss
- 1,47 kWh/24h
- Dimensions
- 570 × 691 × 1.221 mm
- Empty weight
- 90 kg
- Max. pressure
- 10 bar

Vaillant auroSTEP plus VIH S2
Coil cylinder for hot-water production with solar collectors.
- Solar thermal energy
- 250 / 350 l

VIH S2 250/4 B
- Volume
- 246 l
- Coil surface area
- 1,3 m²
- Standby heat loss
- 1,56 kWh/24h
- Dimensions
- 600 × 600 × 1.596 mm
- Empty weight
- 123 kg
- Max. pressure
- 10 bar

VIH S2 350/4 B
- Volume
- 330 l
- Coil surface area
- 1,6 m²
- Standby heat loss
- 1,7 kWh/24h
- Dimensions
- 690 × 690 × 1.778 mm
- Empty weight
- 163 kg
- Max. pressure
- 10 bar

Vaillant auroSTOR exclusive VIH S
Twin-coil cylinder for connecting solar collectors and a boiler.
- Twin coil
- Solar + boiler

VIH S 300/3 MR
- Volume
- 287 l
- Coil surface area
- 1.5 m² solar / 0.8 m² heating
- Standby heat loss
- 1,11 kWh/24h
- Dimensions
- 690 × 775 × 1.929 mm
- Empty weight
- 132 kg
- Max. pressure
- 10 bar

Vaillant allSTOR plus VPS
Buffer tanks storing system water in heat-pump, boiler and solar installations.
- Tampon tank
- 300–2.000 l

VPS 300/3-5
- Volume
- 303 l
- Standby heat loss
- < 1,7 kWh/24h
- Dimensions
- 780 × 828 × 1.833 mm
- Empty weight
- 70 kg
- Max. pressure
- 3 bar

VPS 500/3-5
- Volume
- 491 l
- Standby heat loss
- < 2,0 kWh/24h
- Dimensions
- 930 × 978 × 1.813 mm
- Empty weight
- 90 kg
- Max. pressure
- 3 bar

VPS 1000/3-5
- Volume
- 962 l
- Standby heat loss
- < 2,5 kWh/24h
- Dimensions
- 1.070 × 1.118 × 2.324 mm
- Empty weight
- 145 kg
- Max. pressure
- 3 bar

VPS 1500/3-5
- Volume
- 1.505 l
- Standby heat loss
- < 2,9 kWh/24h
- Dimensions
- 1.400 × 1.448 × 2.362 mm
- Empty weight
- 210 kg
- Max. pressure
- 3 bar

VPS 2000/3-5
- Volume
- 1.917 l
- Standby heat loss
- < 3,3 kWh/24h
- Dimensions
- 1.500 × 1.548 × 2.485 mm
- Empty weight
- 240 kg
- Max. pressure
- 3 bar


VPS 300/3-7
- Volume
- 303 l
- Standby heat loss
- < 1,7 kWh/24h
- Dimensions
- 780 × 828 × 1.833 mm
- Empty weight
- 70 kg
- Max. pressure
- 3 bar

VPS 500/3-7 (B)
- Volume
- 491 l
- Standby heat loss
- < 2,0 kWh/24h
- Dimensions
- 930 × 978 × 1.813 mm
- Empty weight
- 90 kg
- Max. pressure
- 3 bar

VPS 800/3-7
- Volume
- 778 l
- Standby heat loss
- < 2,4 kWh/24h
- Dimensions
- 1.070 × 1.118 × 1.944 mm
- Empty weight
- 130 kg
- Max. pressure
- 3 bar
Which model suits your building?
Let us determine the right equipment and capacity for your building and carry out installation, commissioning and maintenance.