Vaillant – Heat Pumps
Brands›Vaillant›Heat Pumps
Vaillant

Heat Pumps

Monobloc and split air-to-water heat pumps and ground/water-source models for heating, hot water and cooling.

6 series17 models

Vaillant aroTHERM plus

R290 monobloc air-to-water heat pump using a natural refrigerant. Flow temperatures up to 75 °C also allow use in existing radiator-heated buildings.

  • R290 (GWP 0,02)
  • Flow temperature up to 75 °C
  • Heating, hot water, cooling
  • Gece sessiz modu
Manufacturer page ↗
aroTHERM plus

VWL 35/8.1 A 230V

Heating output A7/W35
2,00 kW
COP A7/W35
4,92
Heating output A-7/W35
4,26 kW
SCOP (35 °C)
4,97
Energy class (35 °C)
A+++
Refrigerant
R290 · 0,6 kg
Sound power level
44,1 dB(A)
Dimensions H×W×D
765 × 1.100 × 450 mm
Weight
113 kg
Power supply
230 V / 50 Hz
aroTHERM plus

VWL 55/8.1 A 230V

Heating output A7/W35
2,00 kW
COP A7/W35
4,92
Heating output A-7/W35
5,59 kW
SCOP (35 °C)
4,83
Energy class (35 °C)
A+++
Refrigerant
R290 · 0,6 kg
Sound power level
44,3 dB(A)
Dimensions H×W×D
765 × 1.100 × 450 mm
Weight
113 kg
Power supply
230 V / 50 Hz
aroTHERM plus

VWL 75/8.1 A 230V

Heating output A7/W35
2,67 kW
COP A7/W35
4,94
Heating output A-7/W35
6,94 kW
SCOP (35 °C)
4,98
Energy class (35 °C)
A+++
Refrigerant
R290 · 0,9 kg
Sound power level
46,8 dB(A)
Dimensions H×W×D
965 × 1.100 × 450 mm
Weight
130 kg
Power supply
230 V / 50 Hz

Vaillant aroTHERM pro

Compact single-fan monobloc heat pump delivering 70 °C flow without an electric backup heater.

  • R290
  • 70 °C flow temperature
  • Compact casing
  • myVAILLANT app
Manufacturer page ↗
aroTHERM pro

VWL 55/7.1 A 230V

Heating output A7/W35
3,36 kW
COP A7/W35
4,93
Heating output A-7/W35
4,84 kW
SCOP (35 °C)
5,01
Energy class (35 °C)
A+++
Refrigerant
R290 · 0,5 kg
Sound power level
49 dB(A)
Dimensions H×W×D
750 × 1.104 × 454 mm
Weight
84 kg
Power supply
230 V / 50 Hz
aroTHERM pro

VWL 75/7.1 A 230V

Heating output A7/W35
4,48 kW
COP A7/W35
4,83
Heating output A-7/W35
6,37 kW
SCOP (35 °C)
4,87
Energy class (35 °C)
A+++
Refrigerant
R290 · 0,6 kg
Sound power level
49 dB(A)
Dimensions H×W×D
750 × 1.104 × 454 mm
Weight
90,3 kg
Power supply
230 V / 50 Hz
aroTHERM pro

VWL 115/7.1 A

Heating output A7/W35
7,53 kW
COP A7/W35
5,03
Heating output A-7/W35
11,12 kW
SCOP (35 °C)
4,93
Energy class (35 °C)
A+++
Refrigerant
R290 · 1,05 kg
Sound power level
54,8 dB(A)
Dimensions H×W×D
1.103 × 1.169 × 454 mm
Weight
136,6 kg
Power supply
400 V / 50 Hz

Vaillant aroTHERM perform

High-performance monobloc heat pump up to 20 kW for large homes and small commercial buildings.

  • Up to 20 kW
  • R290
  • 70 °C flow at -15 °C outdoors
  • iQconnect
Manufacturer page ↗
aroTHERM perform

VWL 155/8.1 A Q

Heating output A7/W35
12,63 kW
COP A7/W35
5,43
Heating output A-7/W35
15,48 kW
SCOP (35 °C)
5,44
Energy class (35 °C)
A+++
Refrigerant
R290 · 2,4 kg
Sound power level
49 dB(A)
Dimensions H×W×D
1.233 × 1.897 × 785 mm
Weight
308 kg
Power supply
3/N/PE 400 V / 50 Hz
aroTHERM perform

VWL 205/8.1 A Q

Heating output A7/W35
12,47 kW
COP A7/W35
5,34
Heating output A-7/W35
19,13 kW
SCOP (35 °C)
5,35
Energy class (35 °C)
A+++
Refrigerant
R290 · 2,4 kg
Sound power level
50 dB(A)
Dimensions H×W×D
1.233 × 1.897 × 785 mm
Weight
308 kg
Power supply
3/N/PE 400 V / 50 Hz

Vaillant aroTHERM pure

Economical split system for new buildings, with a compact outdoor unit and an indoor unit containing the hot-water tank and backup heater.

  • Heating, cooling, hot water
  • R32
  • Compact outdoor unit
Manufacturer page ↗
aroTHERM pure

VWL 105/7.2 AS 230V S3

Heating output A7/W35
9,85 kW
COP A7/W35
4,68
Heating output A-7/W35
7,12 kW
Refrigerant
R32 · 1,6 kg
Sound power level
59,4 dB(A)
Dimensions H×W×D
787 × 982 × 427 mm
Weight
82 kg
Power supply
230 V / 50 Hz

Vaillant aroTHERM Split plus

Split air-to-water heat pump with active cooling and up to 40 m of piping between indoor and outdoor units.

  • Split design
  • R32
  • Active cooling
  • Sound Safe
Manufacturer page ↗
aroTHERM Split plus

VWL 35/8.2 AS 230V

Heating output A7/W35
3,54 kW
COP A7/W35
5
Heating output A-7/W35
3,54 kW
Energy class (35 °C)
A+++
Refrigerant
R32 · 1,3 kg
Sound power level
47,5 dB(A)
Dimensions H×W×D
765 × 1.100 × 450 mm
Weight
107 kg
Power supply
230 V / 50 Hz
aroTHERM Split plus

VWL 55/8.2 AS 230V

Heating output A7/W35
4,51 kW
COP A7/W35
4,9
Heating output A-7/W35
4,89 kW
Energy class (35 °C)
A+++
Refrigerant
R32 · 1,3 kg
Sound power level
47,5 dB(A)
Dimensions H×W×D
765 × 1.100 × 450 mm
Weight
107 kg
Power supply
230 V / 50 Hz
aroTHERM Split plus

VWL 75/8.2 AS 230V

Heating output A7/W35
5,07 kW
COP A7/W35
5,2
Heating output A-7/W35
6,39 kW
Energy class (35 °C)
A+++
Refrigerant
R32 · 1,5 kg
Sound power level
48,3 dB(A)
Dimensions H×W×D
960 × 1.100 × 450 mm
Weight
121 kg
Power supply
230 V / 50 Hz

Vaillant flexoTHERM exclusive

Indoor-installed heat pump using ground, groundwater or air as its source; passive cooling with an additional module.

  • Ground / water / air source
  • 5–19 kW
  • Passive cooling option
  • A+++ (35 °C)
Manufacturer page ↗
flexoTHERM exclusive

VWF 57/4

Heating output B0/W35
5,28 kW
COP B0/W35
4,41
Heating output W10/W35
6,32 kW
Seasonal efficiency (35 °C)
%184
Energy class (35 °C)
A+++
Refrigerant
R410A · 1,5 kg
Sound power level
39,8 dB(A)
Dimensions H×W×D
1.183 × 595 × 600 mm
Weight
145 kg
Power supply
230 / 400 V
flexoTHERM exclusive

VWF 86/4

Heating output B0/W35
8,82 kW
COP B0/W35
4,84
Heating output W10/W35
9,94 kW
Seasonal efficiency (35 °C)
%202
Energy class (35 °C)
A+++
Refrigerant
R410A · 2,4 kg
Sound power level
42,4 dB(A)
Dimensions H×W×D
1.183 × 595 × 600 mm
Weight
160 kg
Power supply
230 / 400 V
flexoTHERM exclusive

VWF 117/4

Heating output B0/W35
11,18 kW
COP B0/W35
4,77
Heating output W10/W35
12,88 kW
Seasonal efficiency (35 °C)
%201
Energy class (35 °C)
A+++
Refrigerant
R410A · 2,5 kg
Sound power level
45,2 dB(A)
Dimensions H×W×D
1.183 × 595 × 600 mm
Weight
168 kg
Power supply
230 / 400 V
flexoTHERM exclusive

VWF 157/4

Heating output B0/W35
14,39 kW
COP B0/W35
4,69
Heating output W10/W35
16,68 kW
Seasonal efficiency (35 °C)
%196
Energy class (35 °C)
A+++
Refrigerant
R410A · 3,05 kg
Sound power level
49,9 dB(A)
Dimensions H×W×D
1.183 × 595 × 600 mm
Weight
176 kg
Power supply
230 / 400 V
flexoTHERM exclusive

VWF 197/4

Heating output B0/W35
19,62 kW
COP B0/W35
4,54
Heating output W10/W35
23,00 kW
Seasonal efficiency (35 °C)
%187
Energy class (35 °C)
A+++
Refrigerant
R410A · 3,98 kg
Sound power level
48,4 dB(A)
Dimensions H×W×D
1.183 × 595 × 600 mm
Weight
187 kg
Power supply
230 / 400 V
Technical data compiled from the manufacturer’s Polish website (vaillant.pl ↗). Models and specifications may vary by country and over time; the manufacturer’s current documentation is authoritative. HYDRATERM is an independent installer and service provider for Vaillant products and is not an official representative of the manufacturer.